Д.Уранчимэг
Loading...
Товч нэр
Д.Уранчимэг
Бүтэн нэр
Даваацэрэн Уранчимэг
Латин нэр
Davaatseren Uranchimeg
Эрдмийн цол
Профессор
Харьяалал
ORCID
Scopus Author ID
2 results
Now showing 1 - 2 of 2
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Bevacizumab Monotherapy or Combined with Laser versus Laser Monotherapy in Mongolian Patients with Diabetic Macular Edema(Mongolian National University of Medical Sciences, 2016-06-25) ;Anaraa Toishubai; ;Baasankhuu Jamyanjav ;Sun Taek LimObjectives: To evaluate the efficacy and safety of bevacizumab monotherapy and bevacizumab therapy combined with laser therapy versus laser monotherapy in Mongolian patients with visual impairment due to diabetic macular edema (DME). Methods: One hundred twelve eligible patients, aged ^18 years, with type 1 or 2 diabetes mellitus and best corrected visual acuity (BCVA) in the study eye of 35 to 69 Early Treatment Diabetic Retinopathy Study letters at 4 m (Snellen equivalent: >6/60 or <6/12), and with visual impairment due to center-involved DME were included in the study. Patients were randomized into three treatment groups: (1) intravitreal bevacizumab monotherapy (n = 42), (2) intravitreal bevacizumab combined with laser therapy (n = 35), and (3) laser monotherapy (n = 35). Bevacizumab injections were given for three initial monthly doses and then pro re nata thereafter based on BCVA stability and DME progression. The primary efficacy endpoints were the mean change in BCVA and central retinal subfield thickness from baseline to month 12. Results: Bevacizumab monotherapy and bevacizumab + laser were superior to laser monotherapy in improving the mean change in BCVA letter score from baseline to month 12 (+8.3 and +11.3 vs +1.1 letters; both p ><0.0001). At month 12, a greater proportion of patients gained >10 and >15 letters and had a BCVA letter score >73 (Snellen equivalent: >6/12) with bevacizumab monotherapy (23.8% and 7.1% and 4.8%, respectively) and bevacizumab + laser (57.1% and 28.6% and 14.3%, respectively) versus laser monotherapy (0% and 0% and 0%, respectively). The mean central retinal subfield thickness was significantly reduced from baseline to month 12 with bevacizumab (-124.4 pm) and bevacizumab + laser (-129.0 pm) versus laser (-62.0 pm; both p = 0.002). Conjunctival hemorrhage was the most common ocular event. No endophthalmitis cases occurred. Conclusion: Bevacizumab monotherapy or bevacizumab + laser showed superior BCVA improvements over macular laser treatment alone in Mongolian patients with visual impairment due to DME. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Assessment of Laser in Situ Keratomileusis Flap Predictability by Laser and Moria Microkeratome(Mongolian National University of Medical Sciences, 2023-09-30); ; ; ;Baasankhuu JamyanjavUranchimeg DavaatserenObjective: In the present study, we compared LASIK flap thickness predictability created by a FS laser versus a Moria microkeratome in Mongolian patients. Methods: A total of ninety-six candidates for the LASIK procedure were stratified into two groups: FS laser-assisted and MK flap creation. Flap thickness was determined at five points. The side-cut angle was measured in three directions at the margin interface. LASIK flap assessment was performed one month postoperatively by Spectralis anterior segment optical coherence tomography. Results: Ninety-five participants (190 eyes) were recruited; 190 eyes were stratified to the FS group and 78 eyes to the MK group. The FS group had relatively even flap configurations, and the MK group had meniscus-shaped flaps. Regarding CR-sphere and cylinder, there was significant difference between 2 groups. The mean cylinder was -1.216 ± 0.924 in FS group while it was -0.730 ± 0.738 in MK group. Similarly, the mean sphere was -3.635 ± 2.031 in FS-LASIK group and -2.984 ± 1.502 in MK-LASIK group. The side-cut architecture varied among the two groups. OCT-C and OCT1Temporal values were significantly different between two groups. Conclusion: Improving the predictability of LASIK flap thickness and morphology is significantly important.
