Б.Буянтүшиг
Loading...
Товч нэр
Б.Буянтүшиг
Бүтэн нэр
Болдбаатар Буянтүшиг
Латин нэр
Boldbaatar Buyantushig
Албан тушаал
Багш
Харьяалал
ORCID
Scopus Author ID
Now showing 1 - 2 of 2
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Indoor Levels of Volatile Organic Compounds at Households in Ulaanbaatar City(Mongolian National University of Medical Sciences, 2023-06-30); ; ; ; Objectives: VOCs, or Volatile Organic Compounds, are a group of organic chemicals that can easily evaporate into the air at room temperature. They are called “volatile” because they have high vapor pressure and can readily form vapors or gases at normal atmospheric conditions. To address this knowledge gap, we aimed to assess VOC exposure and its associated health risks.Method: Samples were collected through the adsorbent tube, followed by detachment from the solvent by organic solvents solvent or methanol, and analyzed by gas chromatographic equipment attached with a flame ionization detector (FID). We selected 150 households from the Chingeltei and Bayangol districts in Ulaanbaatar city, specifically sections 4, 5, 6, and 12, to examine the levels of indoor VOCs in this study. We used the nonparametric Mann-Whitney U test to compare medians of VOC levels for two independent groups. Kruskal-Wallis test was carried out to determine if there was any significant difference between medians of VOC levels for more than two independent groups, including the type of paint used, wooden furniture used, and construction year.Results: We found no significant difference in benzene concentration among different types of households (p<0.8112). The highest benzene concentration (0.181 µg/m3) was measured in apartments and houses. Although there was no statistically significant difference between household room types, the kitchen had a higher benzene concentration than other rooms (p<0.8156). Factors such as household total volume, building construction year, and materials used for floors and walls did not significantly affect indoor benzene concentration. Most of the day, the benzene levels exceeded the standards set by the Indoor Air Quality Act of South Korea and the recommended levels by the Health Minister and Construction and Urban Development Minister of Mongolia. In 133 households in Ulaanbaatar city, indoor VOCs, specifically benzene concentration, exceeded the recommended level stated in Order No. A105/08 by the Health Minister and Construction and Urban Development Minister in 2017.Conclusion: Indoor benzene concentration did not vary significantly based on household type, room type, household volume, building construction year, construction wall material, construction floor material, whether new furniture was purchased or the dwelling was repaired and painted within the last two months, proximity to major roads, or indoor smoking status. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Application of an Ultra-Low-Cost Passive Sampler for Light-Absorbing Carbon in Mongolia(MDPI AG, 2023-11) ;Bekbulat, Bujin ;Agrawal, Pratyush ;Allen, Ryan W ;Baum, MichaelLow-cost, long-term measures of air pollution concentrations are often needed for epidemiological studies and policy analyses of household air pollution. The Washington passive sampler (WPS), an ultra-low-cost method for measuring the long-term average levels of light-absorbing carbon (LAC) air pollution, uses digital images to measure the changes in the reflectance of a passively exposed paper filter. A prior publication on WPS reported high precision and reproducibility. Here, we deployed three methods to each of 10 households in Ulaanbaatar, Mongolia: one PurpleAir for PM2.5; two ultrasonic personal aerosol samplers (UPAS) with quartz filters for the thermal-optical analysis of elemental carbon (EC); and two WPS for LAC. We compared multiple rounds of 4-week-average measurements. The analyses calibrating the LAC to the elemental carbon measurement suggest that 1 µg of EC/m3 corresponds to 62 PI/month (R2 = 0.83). The EC-LAC calibration curve indicates an accuracy (root-mean-square error) of 3.1 µg of EC/m3, or ~21% of the average elemental carbon concentration. The RMSE values observed here for the WPS are comparable to the reported accuracy levels for other methods, including reference methods. Based on the precision and accuracy results shown here, as well as the increased simplicity of deployment, the WPS may merit further consideration for studying air quality in homes that use solid fuels.Scopus© Citations 1
