Даваа–Баасан 08:30–20:00 · Бямба 09:00–16:00
Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    The effect of portable HEPA filter air cleaner use during pregnancy on fetal growth: The UGAAR randomized controlled trial
    (Elsevier BV, 2018-12)
    Barn, Prabjit
    ;
    ;
    Ochir, Chimedsuren
    ;
    ;
    BACKGROUND: Fine particulate matter (PM2.5) exposure may impair fetal growth. AIMS/OBJECTIVES: Our aim was to assess the effect of portable high efficiency particulate air (HEPA) filter air cleaner use during pregnancy on fetal growth. METHODS: The Ulaanbaatar Gestation and Air Pollution Research (UGAAR) study is a single-blind randomized controlled trial conducted in Ulaanbaatar, Mongolia. Non-smoking pregnant women recruited at ≤18 weeks gestation were randomized to an intervention (1-2 air cleaners in homes from early pregnancy until childbirth) or control (no air cleaners) group. Participants were not blinded to their intervention status. Demographic, health, and birth outcome data were obtained via questionnaires and clinic records. We used unadjusted linear and logistic regression and time-to-event analysis to evaluate the intervention. Our primary outcome was birth weight. Secondary outcomes were gestational age-adjusted birth weight, birth length, head circumference, gestational age at birth, and small for gestational age. The study is registered at ClinicalTrials.gov (NCT01741051). RESULTS: We recruited 540 participants (272 control and 268 intervention) from January 9, 2014 to May 1, 2015. There were 465 live births and 28 losses to follow up. We previously reported a 29% (95% CI: 21, 37%) reduction in indoor PM2.5 concentrations with portable HEPA filter air cleaner use. The median (25th, 75th percentile) birth weights for control and intervention participants were 3450 g (3150, 3800 g) and 3550 g (3200, 3800 g), respectively (p = 0.34). The intervention was not associated with birth weight (18 g; 95% CI: -84, 120 g), but in a pre-specified subgroup analysis of 429 term births the intervention was associated with an 85 g (95% CI: 3, 167 g) increase in mean birth weight. CONCLUSIONS: HEPA filter air cleaner use in a high pollution setting was associated with greater birth weight only among babies born at term.
    Scopus© Citations 39
  • Some of the metrics are blocked by your 
    Item type:Publication,
    The effect of portable HEPA filter air cleaners on indoor PM2.5 concentrations and second hand tobacco smoke exposure among pregnant women in Ulaanbaatar, Mongolia: The UGAAR randomized controlled trial
    (Elsevier BV, 2018-02)
    Barn, Prabjit
    ;
    ;
    Ochir, Chimedsuren
    ;
    Laagan, Bayarkhuu
    ;
    BACKGROUND: Portable HEPA filter air cleaners can reduce indoor fine particulate matter (PM2.5), but their use has not been adequately evaluated in high pollution settings. We assessed air cleaner effectiveness in reducing indoor residential PM2.5 and second hand smoke (SHS) exposures among non-smoking pregnant women in Ulaanbaatar, Mongolia. METHODS: We randomized 540 participants to an intervention group receiving 1 or 2 HEPA filter air cleaners or a control group receiving no air cleaners. We followed 259 intervention and 253 control participants to the end of pregnancy. We measured one-week indoor residential PM2.5 concentrations in early (~11weeks gestation) and late (~31weeks gestation) pregnancy and collected outdoor PM2.5 data from centrally-located government monitors. We assessed blood cadmium in late pregnancy. Hair nicotine was quantified in a subset (n=125) to evaluate blood cadmium as a biomarker of SHS exposure. We evaluated air cleaner effectiveness using mixed effects and multiple linear regression models and used stratified models and interaction terms to evaluate potential modifiers of effectiveness. RESULTS: The overall geometric mean (GM) one-week outdoor PM2.5 concentration was 47.9μg/m3 (95% CI: 44.6, 51.6μg/m3), with highest concentrations in winter (118.0μg/m3; 110.4, 126.2μg/m3). One-week indoor and outdoor PM2.5 concentrations were correlated (r=0.69). Indoor PM2.5 concentrations were 29% (21, 37%) lower in intervention versus control apartments, with GMs of 17.3μg/m3 (15.8, 18.8μg/m3) and 24.5μg/m3 (22.2, 27.0μg/m3), respectively. Air cleaner effectiveness was greater when air cleaners were first deployed (40%; 31, 48%) than after approximately five months of use (15%; 0, 27%). Blood cadmium concentrations were 14% (4, 23%) lower among intervention participants, likely due to reduced SHS exposure. CONCLUSIONS: Portable HEPA filter air cleaners can lower indoor PM2.5 concentrations and SHS exposures in highly polluted settings.
    Scopus© Citations 79